Features

General Description

VR5700 System

The VR5700 system is used when the test article size or required displacement makes the VR580 shaker the correct choice but test requirements do not demand the full rated shaker performance available from the VR 5800 system.

Download the datasheet

System Components

  • Electrodynamic Shaker VR580
  • Linear Power Amplifier VR545

Options

  • Vibration isolation mounts
  • Pneumatic payload support
  • DuoBase horizontal/vertical table
  • Thermal chamber interface
  • Metric inserts
  • Head plates and fixtures
  • Vibration controller
  • Rack cabinet

System Specifications

Sine Force 225 lbs force peak
Random Force 110 lbf rms random
Shock Force 240 lbf peak shock
Frequency Range DC to 4500 Hz
Max Acceleration 45 g pk, bare table
32 g pk, 2 lb load
15 g pk, 10 lb load
Max Velocity 60 ips pk
Max Displacement Continuous: 1.0 inch pk-pk, bare table
Between stops: 1.2 inch pk-pk, bare table
Power Requirements 3500 VA @ 100, 110, 200, 220 or 240V, 1Ø, 50/60 Hz